본문 바로가기
Guides

Counterbore Size Chart (M3 to M20)

Spec chartsCNC machiningSep 10, 2026

To sink a bolt head into a plate, the drawing must carry the counterbore dimensions. Three values are needed on the drawing: the through hole, the counterbore diameter, and the counterbore depth. The table covers M3–M20 for socket head cap screws, followed by countersinks for flat head screws and drawing notation.

Counterbore Chart (Socket Head Cap Screws)

Unit: mm. Through holes are medium class.

ThreadThrough
hole
Counterbore
diameter
Counterbore
depth
M33.46.53.5
M44.58.04.5
M55.59.55.5
M66.611.06.5
M89.014.08.5
M1011.017.510.5
M1213.520.012.5
M1617.526.016.5
M2022.033.020.5

The counterbore diameter is the bolt head diameter (ISO 4762 dk) plus 1mm of clearance. The counterbore depth is the minimum value: head height (k = thread designation) plus 0.5mm. The head must sit slightly below the plate surface so that another part placed on top does not interfere. Where the head must not protrude, set the depth to head height + 1mm.

Clearance Hole Classes — Fine, Medium, Coarse

ThreadFineMediumCoarse
M33.23.43.6
M44.34.54.8
M55.35.55.8
M66.46.67.0
M88.49.010.0
M1010.511.012.0
M1213.013.514.5
M1617.017.518.5
M2021.022.024.0

Medium is sufficient for general parts. Use fine for assemblies with tight position requirements, and coarse for welded structures or locations that must absorb assembly error. If no class is specified, the manufacturer drills to medium.

Countersink Chart (Flat Head Screws, 90°)

ThreadThrough
hole
Countersink
diameter
Angle
M33.46.7290°
M44.58.9690°
M55.511.2090°
M66.613.4490°
M89.017.9290°
M1011.022.4090°

The countersink diameter is the theoretical head diameter of the flat head screw (with sharp edges). The actual bolt head is 0.3–0.7mm smaller. If the plate is thinner than the countersink depth, the head breaks through, so the plate thickness must be at least (countersink diameter − through hole) ÷ 2. For M6 that is 3.4mm.

Drawing Notation

SymbolMeaningExample
⌴Counterbore⌴⌀11 depth 6.5
⌵Countersink⌵⌀13.4 × 90°
⌀Diameter⌀6.6 thru
↧Depth↧6.5

The order is through hole → counterbore diameter → depth. Write it on one line, such as "⌀6.6 thru, ⌴⌀11 ↧6.5". If you create it with a CAD hole tool (SolidWorks, Fusion 360, etc.), this notation is added automatically.

Common Mistakes

  • Deep counterbore in thin plate — Drawing an M6 counterbore (depth 6.5) in 3T plate breaks through. Plate thickness must be at least counterbore depth + 1.5mm
  • Counterbore on the back face — A counterbore on a face the tool cannot reach needs an extra setup or cannot be machined. First check whether it can be moved to the front face
  • Counterbore diameter equal to the bolt head — The wrench will not fit. The values in the table include wrench clearance

Summary

Use medium class for the through hole, head height + 0.5mm for the counterbore depth, and for flat heads the countersink diameter equals the head diameter (for 90°). On the drawing, write "⌀ through, ⌴⌀ counterbore ↧ depth" in that order.

See Also

These three pages contain every value needed to specify a bolt hole on a drawing.

Source standards: KS B ISO 4762 (socket head cap screw head dimensions), KS B ISO 273 (bolt hole diameters), KS B ISO 10642 (theoretical head diameter of flat head screws). Counterbore diameter and depth are design-practice values with clearance added to the standard dimensions.

Have a part to machine?

Upload a drawing to see your quote.

Sponsorship & lab support

From competition prep to research projects,
we build alongside student teams and labs.

Questions?

KakaoTalk chat
031-509-0523